Analyses

37 analyses

Grouped by study type. Badges name the standards with dedicated calculations (16 in total).

The IEEE 118-bus system after a load flow, fitted to the view.

All analyses

Load flow and optimization

  • AC load flow

    Balanced load flow with the Newton-Raphson, Gauss-Seidel or Z-bus Gauss-Seidel method.

  • DC load flow

    The linearized active-power flow for quick screening.

  • AC/DC load flow

    Combined AC and DC networks with converters, solved together or as separate AC and DC systems.

  • Unbalanced analysis

    Load flow, faults and harmonics in phase coordinates for unbalanced networks.

  • Time-series load flow

    Quasi-static load flows over load and generation profiles.

  • State estimation

    Weighted-least-squares estimation of the network state from measurements.

  • Harmonic analysis

    Harmonic load flow with a compliance check of voltage and current distortion.

    IEEE 519-2014

  • Optimal power flow

    Full AC optimal power flow in polar form, solved with a primal-dual interior-point method.

Short circuit

  • Short circuit to IEC 60909

    Initial, peak and breaking currents with the correction factors of the standard, for maximum and minimum currents.

    IEC 60909-0

  • Short circuit to ANSI/IEEE C37

    First-cycle and interrupting duties for breaker and fuse evaluation.

    IEEE C37.010

  • General fault analysis

    Three-phase, single-line-to-ground, line-to-line and double-line-to-ground faults with branch contributions.

  • DC short circuit

    Short-circuit currents in DC systems with batteries, rectifiers and capacitors.

    IEC 61660

Stability and dynamics

  • Transient stability

    RMS time-domain simulation of disturbances, with a search for the critical clearing time.

  • Small-signal stability

    Eigenvalues, damping ratios and participation factors of the linearized system.

  • Electromagnetic transients

    EMT simulation of switching and fault events, including statistical switching studies.

  • Voltage stability

    P-V and Q-V curves, including continuation P-V curves to the nose point.

  • Motor starting

    Voltage dips and acceleration while large motors start.

Contingency and reliability

  • Contingency analysis

    N-1 outages and N-2 branch pairs with overload and voltage violations.

  • Cascading outages

    How tripped lines can overload others, on a DC network model.

  • Generation adequacy

    Loss-of-load expectation and energy (LOLE, LOEE), frequency and duration.

  • Composite adequacy

    Generation and transmission together (hierarchical level II).

  • Distribution reliability

    SAIFI and SAIDI of feeders, and supply-point reliability by minimal cut sets.

Protection and safety

  • Protection coordination

    Time-current curves, sequence of operation and suggested relay settings.

    IEC 60255-151 / IEEE C37.112IEEE 242

  • Arc flash

    Incident energy and arc-flash boundaries, with labels and energized work permits.

    IEEE 1584-2018NFPA 70E

  • Arc energy (DGUV)

    Arc energy and protection levels following the German DGUV guidance.

    DGUV 203-077

  • Fault protection

    Automatic disconnection checks for low-voltage installations.

    IEC 60364

  • Ground grid design

    Grid resistance and touch and step voltages of substation earthing grids.

    IEEE 80

  • Insulation co-ordination

    Withstand voltages and clearances from representative overvoltages.

    IEC 60071-2

  • Lightning performance

    Back-flashover and shielding-failure rates of overhead lines.

    CIGRE TB 63

Equipment sizing

  • Cable sizing

    Cross-sections from current, voltage drop and short-circuit withstand, and a check of every cable after a load flow.

    IEC 60364

  • Cable rating

    Continuous current ratings of single-core, three-core and pipe-type cables.

    IEC 60287

  • Battery sizing

    Stationary battery capacity from duty cycles.

    IEEE 485

  • Transformer loading

    Hot-spot temperature and ageing of oil-immersed transformers.

    IEC 60076-7

Operation and planning

  • Feeder reconfiguration

    Switch positions for minimum losses.

  • Load allocation

    Distribute measured feeder demand over the connected loads.

  • Capacitor placement

    Locations and sizes of capacitor banks.

  • Hosting capacity

    How much new generation each bus can take within limits.

Standards

These standards have dedicated calculation code in the engine, not just a reference in a menu.

Standards implemented by PowerGridTools
StandardWhat PowerGridTools calculates
IEC 60909-0 Short-circuit currents in three-phase AC systems
IEEE C37.010 AC high-voltage circuit breakers: short-circuit duties (ANSI)
IEC 61660 Short-circuit currents in DC auxiliary installations
IEEE 1584-2018 Arc-flash hazard calculations
NFPA 70E Arc-flash labels, energized work permits and shock boundaries
DGUV 203-077 Arc energy and protection levels (German guidance)
IEC 60287 Current rating of electric cables
IEC 60364 Low-voltage installations: cable selection and fault protection
IEEE 519-2014 Harmonic control: distortion limits
IEC 60255-151 / IEEE C37.112 Inverse-time relay characteristics
IEEE 242 Protection and coordination practice
IEEE 80 Safety in AC substation grounding
IEEE 485 Sizing lead-acid batteries for stationary applications
IEC 60076-7 Loading guide for oil-immersed power transformers
IEC 60071-2 Insulation co-ordination: application guide
CIGRE TB 63 Lightning performance of overhead lines

Which analyses are available can depend on the package. Standards are trademarks of their publishers; PowerGridTools is not affiliated with them.