Analyses
37 analyses
Grouped by study type. Badges name the standards with dedicated calculations (16 in total).
All analyses
Load flow and optimization
-
AC load flow
Balanced load flow with the Newton-Raphson, Gauss-Seidel or Z-bus Gauss-Seidel method.
-
DC load flow
The linearized active-power flow for quick screening.
-
AC/DC load flow
Combined AC and DC networks with converters, solved together or as separate AC and DC systems.
-
Unbalanced analysis
Load flow, faults and harmonics in phase coordinates for unbalanced networks.
-
Time-series load flow
Quasi-static load flows over load and generation profiles.
-
State estimation
Weighted-least-squares estimation of the network state from measurements.
-
Harmonic analysis
Harmonic load flow with a compliance check of voltage and current distortion.
IEEE 519-2014
-
Optimal power flow
Full AC optimal power flow in polar form, solved with a primal-dual interior-point method.
Short circuit
-
Short circuit to IEC 60909
Initial, peak and breaking currents with the correction factors of the standard, for maximum and minimum currents.
IEC 60909-0
-
Short circuit to ANSI/IEEE C37
First-cycle and interrupting duties for breaker and fuse evaluation.
IEEE C37.010
-
General fault analysis
Three-phase, single-line-to-ground, line-to-line and double-line-to-ground faults with branch contributions.
-
DC short circuit
Short-circuit currents in DC systems with batteries, rectifiers and capacitors.
IEC 61660
Stability and dynamics
-
Transient stability
RMS time-domain simulation of disturbances, with a search for the critical clearing time.
-
Small-signal stability
Eigenvalues, damping ratios and participation factors of the linearized system.
-
Electromagnetic transients
EMT simulation of switching and fault events, including statistical switching studies.
-
Voltage stability
P-V and Q-V curves, including continuation P-V curves to the nose point.
-
Motor starting
Voltage dips and acceleration while large motors start.
Contingency and reliability
-
Contingency analysis
N-1 outages and N-2 branch pairs with overload and voltage violations.
-
Cascading outages
How tripped lines can overload others, on a DC network model.
-
Generation adequacy
Loss-of-load expectation and energy (LOLE, LOEE), frequency and duration.
-
Composite adequacy
Generation and transmission together (hierarchical level II).
-
Distribution reliability
SAIFI and SAIDI of feeders, and supply-point reliability by minimal cut sets.
Protection and safety
-
Protection coordination
Time-current curves, sequence of operation and suggested relay settings.
IEC 60255-151 / IEEE C37.112IEEE 242
-
Arc flash
Incident energy and arc-flash boundaries, with labels and energized work permits.
IEEE 1584-2018NFPA 70E
-
Arc energy (DGUV)
Arc energy and protection levels following the German DGUV guidance.
DGUV 203-077
-
Fault protection
Automatic disconnection checks for low-voltage installations.
IEC 60364
-
Ground grid design
Grid resistance and touch and step voltages of substation earthing grids.
IEEE 80
-
Insulation co-ordination
Withstand voltages and clearances from representative overvoltages.
IEC 60071-2
-
Lightning performance
Back-flashover and shielding-failure rates of overhead lines.
CIGRE TB 63
Equipment sizing
-
Cable sizing
Cross-sections from current, voltage drop and short-circuit withstand, and a check of every cable after a load flow.
IEC 60364
-
Cable rating
Continuous current ratings of single-core, three-core and pipe-type cables.
IEC 60287
-
Battery sizing
Stationary battery capacity from duty cycles.
IEEE 485
-
Transformer loading
Hot-spot temperature and ageing of oil-immersed transformers.
IEC 60076-7
Operation and planning
-
Feeder reconfiguration
Switch positions for minimum losses.
-
Load allocation
Distribute measured feeder demand over the connected loads.
-
Capacitor placement
Locations and sizes of capacitor banks.
-
Hosting capacity
How much new generation each bus can take within limits.
Standards
These standards have dedicated calculation code in the engine, not just a reference in a menu.
| Standard | What PowerGridTools calculates |
|---|---|
| IEC 60909-0 | Short-circuit currents in three-phase AC systems |
| IEEE C37.010 | AC high-voltage circuit breakers: short-circuit duties (ANSI) |
| IEC 61660 | Short-circuit currents in DC auxiliary installations |
| IEEE 1584-2018 | Arc-flash hazard calculations |
| NFPA 70E | Arc-flash labels, energized work permits and shock boundaries |
| DGUV 203-077 | Arc energy and protection levels (German guidance) |
| IEC 60287 | Current rating of electric cables |
| IEC 60364 | Low-voltage installations: cable selection and fault protection |
| IEEE 519-2014 | Harmonic control: distortion limits |
| IEC 60255-151 / IEEE C37.112 | Inverse-time relay characteristics |
| IEEE 242 | Protection and coordination practice |
| IEEE 80 | Safety in AC substation grounding |
| IEEE 485 | Sizing lead-acid batteries for stationary applications |
| IEC 60076-7 | Loading guide for oil-immersed power transformers |
| IEC 60071-2 | Insulation co-ordination: application guide |
| CIGRE TB 63 | Lightning performance of overhead lines |